Airvo™ 2 (Device Only)
A high-flow system delivering high humidification designed to treat a variety of medical needs.
The AIRVO 2 is a humidifier with integrated flow generator that delivers high flow warmed and humidified respiratory gases to spontaneously breathing patients though a variety of patient interfaces.
The AIRVO 2 is for the treatment of spontaneously breathing patients who would benefit from receiving high flow warmed and humidified respiratory gasses. This includes patients who have had upper airways bypassed. The flow may be from 2-60L/min depending on the patient interface.
*NASAL CANNULAS , Water Chamber and Tubes NOT INCLUDED*
Find the Nasal Cannulas HERE!
Find the Watter Chamber HERE!
Find the Tubes HERE!
Proven effective
Optiflow high flow therapy has been proven to be an effective therapy for:
- acute hypoxemia respiratory failure
- post-extubation respiratory support
- post-operative respiratory support
- immunocompromised patients with acute hypoxemia
- patients with COPD.
Evidence-based practice guidelines are emerging for a variety of clinical applications.
Transportable
A compact system with a built-in flow generator means there’s no need for a noisy, heavy air compressor to transport the Airvo 2. Add a suitable UPS, and you’re ready to go.
Interfaces for all applications
A variety of interfaces have been designed for the broad applications of NHF in mind, nasal cannula, Tracheostomy and mask.
Broad flow range
A broad flow range (2 to 60 L/min) takes your patients from the most acute environments (ICU and ED) to the home.
Dimensions | 295 mm x 170 mm x 175 mm (11.6" x 6.7" x 6.9") |
Weight | 4.8 lb - unit only; 7.5 lb packaged |
Humidity Output | Complies with ISO 8185:2007 standard |
Flow Settings | 10 to 60 L/min (increments 5 L/min) - default |
Flow Settings | 2 to 25 L/min (increments 1 L/min) - junior mode |
Patient Interfaces | F&P Optiflow+ nasal cannulas |
Humidity performance |
>35 mg/L at 37°C target |
Warm up time |
10 minutes to 31°C (88 °F) 30 minutes to 37°C (98.6 “F) Using a MR290 chamber with of 35 L/min an starting temperature 23 + 2 °C |
Sound pressure level |
Alarms exceed 45dbA @ 1m |
Auditory alarm Pressure |
115 seconds |
Expected service life | 5 years |
Target temperature settings | 37, 34, 31 °C |
Maximum temperature of delivered gas | 43 °C (109 °F) |
Maximum surface temperature of applied parts | 44 °C (111 °F) |
Flow range (default) | 10-60 L/min |
Maximum oxygen input | 60L/min |
Oxygen analyzer accuracy |
< + 4 % (within the range of 25-95% O2) |
Altitude |
0 - 2000 m (6000 ft) |
Mode of operation |
Continuous operation |
Airvo Instructions
VIDEO Instroduction: